Autotransformer - Split Phase 120/240V - 100AMP
The Autotransformer: for step up, step down and split phase balancing An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.
Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity. Theoretically, the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 7,2 kVA. In case of 20A unbalance, the practical maximum will be 30 x 120 + 10 x120 = 4,8kVA, or 67% of the theoretical maximum. The solution is an Autotransformer. By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the windings of the Autotransformer. The current through both 120V wires of the split phase supply will be 30A.
Temperature protected In case of overheating, the Autotransformer is disconnected from the supply. Reset is manual. Ground relay for use with Multi or Quattro Inverter/Chargers included When operating in inverter mode, the neutral output of the inverter/charger must be connected to ground to guarantee proper functioning of a GFCI. In case of a split phase supply the neutral must be grounded. For this purpose a grounding relay is built in the autotransformer’s enclosure. The relay is controlled by the 230/240V Multi or Quattro. (The internal grounding relay in the 230/240V Multi or Quattro must be disabled)
An alternative to stacked inverters The alternative to stacking two 120V inverters to provide a 120/240V split phase supply is a 240V inverter with an additional Autotransformer.
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
Please contact your dealer for any returns, repairs or support issues related to this product.
Lots of wiring - no leaks! Be sure to run ALL the wires through BEFORE completing the run!
Seaview White Plastic Vertical Cable Seal f/Multiple Wires Up to 10.6mm/0.5"
Ari Storch
"Currently" super happy.
Installed on Yanmar 4JH57 engines with Zeus Controllers - HOLY WOW power. Losing some power at top end but overall very satisfied. Will do a long term review later. Talk about power - hope to never need my generator again!
ARCO Zeus A8000 48V High Output Alternator - Isolated Ground
Magalie Laniel
Great design but fail fast in the caribbean sun...
We bought these boots in 2022, and are buying new ones 3 years later. We love the design and the fact that they are easy to remove for inspection of the rig.
Spreader Boots
Jon
Victron
Review for electrical system components:
• Victron Lithium Battery 24VDC 300Ah NG Smart LifePO4 (x4)
• Victron Lynx Smart BMS 500 NG (M10)
• Victron Lynx Distributor w/M10 Terminals (x2)
• Victron MultiPlus-II 24/5000 120-95 120V (x2)
• Victron Phoenix Smart IP43 Charger 24/25 (1+1) 120-240VAC (x5)
• Victron Cerbo GX MK2 w/ Victron GX Touch 70 Flush Mount Display
• Z Bar - Class T battery link Bundle w/ Blue Sea 5119 300AMP Class T Fuse (x4)
• Victron Orion XS 1400 DC-DC Battery Charger (x2)
• Victron SmartSolar MPPT Charge Controller - 100V - 30AMP - UL Approved (x4)
Complete upgrade of my Irwin 54 Sloop electrical system –
Phase 1 – Remove 9KW generator, install 30KW LifePO4 battery system, inverter chargers, battery chargers, etc. wired for worldwide shore power capability to ABYC standards. Installation made possible with guidance and support from Andre Cormier and The Yacht Rigger.
Victron Lithium Battery 24VDC 300Ah NG Smart LifePO4
Lacy Bryan White
Great Product!
I was amazed with the product especially, the attention to detail. I was also very pleased with the help and recommendations I received from Chris Wilcher. He made the purchase very easy.