Use this bar to show information about your cookie policy.
Description
C-Series ELCI Main Circuit Breaker - Double Pole 230V AC 32A
Features:
Trips on short circuit, overload, or leakage to ground
Front panel mount—installed in a power distribution panel
Specifications:
Amperage: 32A
Actuator Style: Flat actuator
Poles: 2
Ignition Protected: Yes
Maximum Voltage: 240V AC per pole
Circuit Breaker Type: Magnetic Hydraulic - trip free
Interrupt Capacity: 5000A
Minimum Operating Temperature: -35 degrees C
Maximum Operating Temperature: 66 degrees C
Leakage Trip Amps: 30mA
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6in-lb (0.68 Nm)
Switching Cycles: 10000
Weight: 1.05 lbs (0.48kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.